Transactions of Japanese Society for Medical and Biological Engineering
Online ISSN : 1881-4379
Print ISSN : 1347-443X
ISSN-L : 1347-443X
Proceedings
A method for evaluating estimation accuracy of instantaneous heart rate
Hidenao NagaiMitsuki AiharaMasaki SugaIchiro JojaKazuo Yana
Author information
JOURNAL FREE ACCESS

2015 Volume 53 Issue Supplement Pages S335-S339

Details
Abstract
This paper shows a method of evaluating the accuracy of the instantaneous heart rate reconstruction. A general evaluation scheme and a new evaluation index have been proposed and three reconstruction methods, Derivative of Cubic Spline Interpolation (DCSI), Resampled Instantaneous Heart Rate (RIHR) and Spline Smoothed Instantaneous Heart Rate (SIHR), are compared. Computer simulation based on Integrated pulse frequency modulation (IPFM) model with modulating signals having 1/f power spectrum characteristics has been carried out for comparison. A new index named the Effective bandwidth showed better performance in the following order, i.e. DCSI > SIHR > RIHR. It is also noted that SIHR have less estimation bias compared to DCSI in high frequency region. The method will be useful for precise characterization of the frequency domain characteristics of the heart rate.
Content from these authors
© 2015 Japanese Society for Medical and Biological Engineering
Previous article Next article