細菌培養下における培養液の電気インピーダンス計測
四および二電極法による培養液のインピーダンス変化の特性
木吉 英典橋本 基三池 秀敏蛯名 良雄宮地 隆興
著者情報
ジャーナル フリー

1981 年 19 巻 1 号 p. 35-39

詳細
抄録
The four-electrode method has many advantages in monitoring the impedance change in the solution of growing bacteria. To examine the reason for good reproducibility, the characteristics of impedance change are measured by changing the material of metal electrodes, the length between electrodes, source frequency and amplitude of applied constant current, as well as the magnitude of the series resistance R0. The R0 is inserted to obtain constant amplitude of current. The results are summarized as follows :
(1) To monitor the rate of impedance change in the solution, the constant current method is convenient.
(2) The four-electrode method used together with constant current can give stable impedance change for any metal wire electrodes with 0.7 mmφ.
(3) Cheap stainless steel wire is favorable for metal electrodes.