Bulletin of JSME
Online ISSN : 1881-1426
Print ISSN : 0021-3764
Study on Annular Mist Flow in Pipe : 1st Report, Investigation of the Non-equilibrium Length and Changes of Some Factors in the Non-equilibrium Region
Heishichiro TAKAHAMAOsamu OKADAYukihiro HAMADA
Author information
JOURNAL FREE ACCESS

1980 Volume 23 Issue 185 Pages 1849-1856

Details
Abstract
An annular mist flow using air and water at room temperature has been studied experimentally in a vertical pipe with a nozzle along the axis of the pipe for supplying liquid. Observations were made of flow patterns of liquid on the inner surface of the pipe, and measurements were made of pressure losses in pipe, profiles of radial distribution of liquid droplets and total flow rates of the liquid droplets. Changes of these four factors along the pipe were measured in the non-equilibrium region. It was found that the non-equilibrium length should be decided by a position where any changes in the four factors mentioned above could not be recognized in the axial direction. For relatively high velocities of air, i.e., for apparent gaseous Reynolds number Rego ≥9.4×104, it was ascertained that the annular mist flow reached equilibrium at a distance of 170-190 diameters from the nozzle outlet when apparent liquid Reynolds number Relo = 62.1-183.6.
Content from these authors
© The Japan Society of Mechanical Engineers
Previous article Next article
feedback
Top