1986 年 29 巻 247 号 p. 113-118
Shaft displacement due to dump casing deformation which occurs when external piping forces and moments are applied was investigated. The test pump was an axially split, single-stage double suction volute type with foot support. An analysis by FEM(MSC/NASTRAN) was performed and considerable good agreement was obtained with actual measurement. It was found that shaft displacement due to pump casing deformation can not be neglected for pumps with foot support. In API 610-6th standard, limit of shaft displacement is 0.127 mm for pumps which have suction bores 300 mm or less. But according to this investigation, it is reasonable with pumps having suction bore diameters larger than 300 mm to enlarge this limitation. Effects of pump size and casing thickness on shaft displacement were investigated by FEM. The possibility of a galling of the casing wearing ring and a considerable leakage from mechanical seal caused by piping loads was also investigated.
JSME International Journal Series C Mechanical Systems, Machine Elements and Manufacturing
JSME International Journal Series B Fluids and Thermal Engineering
JSME International Journal Series A Solid Mechanics and Material Engineering
JSME international journal. Ser. C, Dynamics, control, robotics, design and manufacturing
JSME international journal. Ser. 3, Vibration, control engineering, engineering for industry
JSME international journal. Ser. A, Mechanics and material engineering
JSME international journal. Ser. 1, Solid mechanics, strength of materials