Bulletin of JSME
Online ISSN : 1881-1426
Print ISSN : 0021-3764
Fluctuation of Void Ratio in Two-Phase Flow : 2nd Report, Analysis of Flow Configuration Considering the Existence of Small Bubbles in Liquid Slugs
Koji AKAGAWATadashi SAKAGUCHI
著者情報
ジャーナル フリー

1966 年 9 巻 33 号 p. 104-110

詳細
抄録

In this paper, the flow configuration of the two-phase slug flow, which contains small bubbles in the liquid slug has been analysed. The experiment has been carried out for air-water two-phase upward flow in 27.6 mm ID glass tube, using the electrode probe which indicates the void ratio fluctuation. The new parameters such as the ratios of the large bubble (Taylor bubble) volume (fdB) and of small bubbles volume in liquid slug (fdS) to a control volume, the void ratio in gas slug section (fd1) and the void ratio in liquid slug section (fd2) have been introduced. These parameters except fd1 are given experimentally as the funtion of mean void ratio fd only. They are as follows : fdB=fd1.8 fdS=fd(1-fd0.3) fd1=<0.65> fd2=fd1.8

著者関連情報
© The Japan Society of Mechanical Engineers
前の記事 次の記事
feedback
Top