JSME International Journal Series B Fluids and Thermal Engineering
Online ISSN : 1347-5371
Print ISSN : 1340-8054
ISSN-L : 1340-8054
PAPERS
Simplified Model Predicting Contact-Line-Length Density at Critical Heat Flux Based on Direct Observation of Boiling Structure
Shigefumi NISHIOHiroaki TANAKA
著者情報
ジャーナル フリー

2002 年 45 巻 1 号 p. 72-78

詳細
抄録
Great efforts have been made to attain a good understanding of boiling heat transfer, but we have a poor understanding for the boiling structures in high heat-flux boiling. For example, there are still opposing opinions for the mechanism of the critical heat flux in saturated boiling and there are no rigorous models for that in subcooled boiling. In the present paper, the nucleation site density (NSD) was measured using high-speed video pictures and an image processing technique. The video pictures were taken from below the boiling surface made of single crystal sapphire with a total reflection technique. Based on the experimental results of NSD, a simplified model predicting the contact-line-length density (CLLD) at CHF is proposed.
著者関連情報
© 2002 by The Japan Society of Mechanical Engineers
前の記事 次の記事
feedback
Top