JSME International Journal Series B Fluids and Thermal Engineering
Online ISSN : 1347-5371
Print ISSN : 1340-8054
ISSN-L : 1340-8054
Cavitation, from Cav 2001
Flow Measurement in Helical Inducer and Estimate of Fluctuating Blade Force in Cavitation Surge Phenomena
Akinori FURUKAWAKoichi ISHIZAKASatoshi WATANABE
著者情報
ジャーナル フリー

2002 年 45 巻 3 号 p. 672-677

詳細
抄録
An attachment of inducer is a powerful method to improve the cavitation performance of a turbo-pump. Cavitation surge phenomena, occurring under the severe suction pressure at a partial flow rate, is focused in the present paper. Flow measurements were carried out at the inlet and outlet sections of a flat-plate helical inducer with the solidity of 2.0 and tip blade angle of 11° by using a total-head yaw-meter with a phase locked sampling method in one period of the shaft rotation or the cavitation oscillation. Time variation of the flow distributions during the oscillation is clarified with observed cavitation behaviors. After these results are compared with those in conditions just before and after the oscillations, the fluctuating blade forces are estimated from the blade to blade distributions of casing wall pressures measured in these conditions.
著者関連情報
© 2002 by The Japan Society of Mechanical Engineers
前の記事 次の記事
feedback