設計工学・システム部門講演会講演論文集
Online ISSN : 2424-3078
セッションID: 3207
会議情報
3207 可視・赤外計測結果のデジタル画像処理による石油タンクスラッジ堆積高さの測定(OS13 貯槽の防災と設計III)
阪上 隆英込山 貴仁佐藤 大輔山田 實光田 司久保 司郎
著者情報
会議録・要旨集 フリー

詳細
抄録
Instrumentation for locating sludge level in crude oil storage tanks was developed based on surface temperature distribution on the side wall of the tank. Temperature difference was observed between crude oil portion and sludge portion due to their different thermal properties. Data fusion technique was employed for processing temperature data measured by infrared thermography and visible photograph data measured by a digital camera, which enables us to locate the sludge level and to measure its height quantitatively. Experimental studies were made on the applicability of the proposed technique through field tests of crude oil tanks for petroleum stockpiling in Japan. Influences of weather, tank orientation, crude oil type on the measurement were investigated.
著者関連情報
© 2005 一般社団法人 日本機械学会
前の記事 次の記事
feedback
Top