環境工学総合シンポジウム講演論文集
Online ISSN : 2424-2969
会議情報
404 高効率廃棄物発電プラントの実証試験 : ボイラ用新耐食合金の耐久性評価
川原 雄三折田 寛彦高橋 和義中川 裕二
著者情報
会議録・要旨集 フリー

p. 309-312

詳細
抄録
In order to develop a 9.8MPa/500℃ highly efficient waste-to-energy plant with 30% electric efficiency, application of highly corrosion resistant materials for superheater and corrosion resistant coatings for waterwall are indispensable. The corrosion lives of six conventional and five newly developed superheater tube materials and three coatings were demonstrated for two years in the NEDO waste-to-energy pilot plant. As the results of the demonstration test, an excellent durability of more than 10 years for Ni-Cr-Mo alloys of 3rd superheater and for Ni-Cr-Fe alloys of 2nd superheater were clarified. Also, corrosion resistant coatings of alloy 625 weld overlay and NiCrSiB alloy HVOF spraying applied on waterwall showd a good durability. From the results mentioned above, technical reliability of a 9.8MPa/500℃ waste-to-energy boiler having long durability were demonstrated.
著者関連情報
© 2000 一般社団法人 日本機械学会