Applicability of simple method of dioxin measurement for combustion control
Katsuya KAWAMOTOTakashi IMAIZUMIHaruo MIYATANorio YASUDAShogo KOYOSHI
Author information
CONFERENCE PROCEEDINGS FREE ACCESS

Pages 251-254

Details
Abstract
To examine the possibility of using the TOX (Total Organic Halogen-an alternative index of DXNs) as an operational management of the DXNs reduction control, we have studied what relationship exists between DXNs and TOX of the exhaust gas from an incineration facility in terms of the distribution of combustion air, the injection volume of activated carbon, and the BF entrance temperature. We consequently have found that the data from both DXNs and TOX show the same trend. We also have investigated the relationship between DXNs and TOX at the facility where the new type of DXNs absorbent is used, and have confirmed that the relationship is different between new type of DXNs absorbent and the traditional activated carbon.
Content from these authors
© 2002 The Japan Society of Mechanical Engineers