抄録
This Paper describes the reduction of dioxins and other components with active carbon tower. These tests have been carried out at actual fluidized bed type incineration plant using bench scale equipment. The reduction rate of dioxins have kept after 3000 hours test. Dioxins concentration of the adsorber outlet flue gas (0.0015ng-TEQ/Nm3) was lower level than Japanese regulation (0.1ng-TEQ/Nm3) Active carbon tower is effective for reduction of dioxins and other Chlorinated organic compounds (ex. Hexachlorobenzene, Polychloronaphthalene)