309 温水曝気による VOC 含有水の処理システム
瀬尾 敦子
著者情報
会議録・要旨集 フリー

p. 236-238

詳細
抄録
The remediation of VOC contaminated soil and underground water has been an social problem nationwide. We recently developed a new water treatment system for VOCs abatement by using a combination technology of aeration and combustion. In this system, VOC contaminated water is at first aerated to get VOCs out of water. The VOCs containing air is premixed with city gas and then burned. Combustion heat is used to warm the untreated water, so that the water is aerated around the temperature of 40℃. Comparing with the exiting treatment method of activated carbon adsorption, this system has higher VOCs removal rates without generating industry wastes. The burned gas was analyzed to check the concentration of dioxins and unburned VOCs.
著者関連情報
© 2003 一般社団法人 日本機械学会