抄録
Generally, the specifications of PV modules are represented by nominal values on the panels of PV modules. We assumed that the rated values of PV modules are different to nominal values. It is necessary to analyze the nominal maximum output, the rated maximum power output and the power output of reconstructed string of PV Array installed on the roof of the building We studied the difference between the nominal maximum output and the rated maximum power output, dispersion of the maximum power output for PV arrays and proposed the constructing method of string of PV array. As a result, the rated maximum power output is 45W, 229W higher than the nominal maximum output for p-Si arrays and CIS arrays respectively. The maximum of power output of CIS array increased about 2.53% by the reconstructing method of string.