The Proceedings of the Symposium on Environmental Engineering
Online ISSN : 2424-2969
2012.22
Session ID : 306
Conference information
306 Development of SNCR method by Activated Ammonia Assisted by vacuum ultra violet
Akihiro TakeyamaShinji KanabaraMitsuhiro KondoNobuyuki HishinumaMegumi MasuiYutaka MurataHiroshi Motiromi
Author information
CONFERENCE PROCEEDINGS FREE ACCESS

Details
Abstract
To broaden and lower the temperature window of the selective non catalytic reduction (SNCR) of nitric oxide (NO), the use of activated ammonia as the reduction agent was examined. A xenon excimer lamp emitting a wavelength of 172 nm (i.e., vacuum ultraviolet; VUV) was employed as the excitation source for molecular ammonia The effects of reaction temperatures, oxygen concentrations, and length between an excimer lamp and a reactor on NO removal were investigated in a lab-scale plug flow reactor.
Content from these authors
© 2012 The Japan Society of Mechanical Engineers