環境工学総合シンポジウム講演論文集
Online ISSN : 2424-2969
セッションID: 440
会議情報
440 直交表-GAのハイブリッド解析法を用いた複合エネルギーシステムの計画方法(エネルギー有効利用(4))
渡邊 聖司小原 伸哉棟朝 雅晴
著者情報
会議録・要旨集 フリー

詳細
抄録
Generally, the output characteristics of the energy apparatus are nonlinear. Furthermore, because multiple power sources are used in microgrids, many variables must be considered to optimize the system. Orthogonal tables are employed in this paper to reduce the complexity of the problem to plan the optimal operation method of a compound energy system. Therefore, orthogonal table used to experimental design are employed in this presentation to reduce the complexity of the problem to plan the optimal operation method of a compound energy system. The initial values of design parameters of the system near the optimum operation method are determined using result of orthogonal table experiment and the factor effect diagram. Next, the optimal solution is obtained by introducing this result as initial values of GA. The proposed analysis method is available for improvement of the analysis precision by the increase of the number of gene models and the increase of the design parameters. Therefore, proposed analyzing method was overcame weak points of the optimal calculation of conventional simple GA.
著者関連情報
© 2012 一般社団法人 日本機械学会
前の記事 次の記事
feedback
Top