環境工学総合シンポジウム講演論文集
Online ISSN : 2424-2969
セッションID: 309
会議情報
309 気体収束爆轟型液体殺菌装置の開発(大気・水環境保全・改善技術(3))
鈴木 実紺野 隼
著者情報
会議録・要旨集 フリー

詳細
抄録
The imploding detonation of a propane-oxygen mixture was used to generate underwater shock waves in a sample holder. We used the three kinds of experimental apparatuses whose the inner diameters of main combustion chamber are 60 mm, 150 mm, and 400 mm. The experimental results show that maximum pressure at the implosion center was 150 to 18000 times higher than the initial pressure. Although the maximum pressure in the exit of a sample holder changes with the sizes of experimental apparatus, pressure increase speed is almost constant. We found that the peak pressure in the end of a sample holder can be increased by expansion of the size of the main combustion chamber, and that we can perform scale-up and automatic operation of sterilization equipment.
著者関連情報
© 2014 一般社団法人 日本機械学会
前の記事 次の記事
feedback
Top