ガラス溶解炉半乾式脱硫装置へのプラズマ複合脱硝技術の応用
*河田 将志正川 浩貴黒木 智之藤島 英勝山本 柱大久保 雅章
著者情報
会議録・要旨集 認証あり

詳細
抄録

Nitrogen oxides (NOx) and sulfur oxides (SOx) are the major components of environmental pollution; therefore they should be removed. In this study, NO oxidation process by using ozone gas and NOx removal process by using Na2SO3 solutions combined with semi-dry desulfurization equipment to glass melting furnace were investigated. Experiments were carried out with varying gas-liquid reaction time in the lab-scale experiment and Na2SO3 concentration in the pilot-scale experiment. In the lab-scale experiment, NOx removal efficiency was reached 64.9 % in maximum. Furthermore, in the pilot-scale experiment, when the ratio of the amount of ozone gas to the amount of NO in the exhaust gas was 23 %, NOx removal efficiency was reached up to 17.0 %. There was no effect on desulfurization by applying plasma-chemical hybrid process to semi-dry desulfurization equipment.