環境工学総合シンポジウム講演論文集
Online ISSN : 2424-2969
セッションID: 111
会議情報

複数の計測器を連携させた実稼働TPAによる寄与分離技術について
*山本 高志岡田 隆志野土 雄太吉田 準史
著者情報
会議録・要旨集 認証あり

詳細
抄録

Operational TPA was developed to obtain contributions with small man-hour. In the method, all reference and response signals are necessary to be measured at exactly same timing by single measurement system. However, this occasionally requires large measurement system depending on the products and may decrease the applicability of the method. In this study, we propose a method for obtaining high contributing part (reference point) to the response point at the operational condition by OTPA using several measurement systems. In the proposed method, the measurement timing gap among measurement systems is estimated using the estimation error of OTPA between calculated and measured response signals. As a verification of the proposed method, we applied this procedure to a simple vehicle model and compared the obtained contribution with the contributions by OTPA using single measurement system. As the result, the contribution of the proposed method was verified to have an ability to obtain the correct contribution by several measurement systems.

著者関連情報
© 2021 一般社団法人 日本機械学会
前の記事 次の記事
feedback
Top