会議情報
1712 気液二相流のための超音波・電気伝導・画像処理を用いた複合計測システムの基礎研究(2)(OS17-3 超音波を利用した流動場の計測,OS17 超音波を利用した流動場の計測,オーガナイズドセッション)
重藤 雅貴木倉 宏成有冨 正憲
著者情報
会議録・要旨集 フリー

詳細
抄録
To measure the main parameter of the gas-liquid two-phase flow at the same time, the compound measurement system was developed. The compound measurement system is composed of Ultrasonic Time-Domain Correlation method (UTDC), Wire Mesh Tomography (WMT), and Digital Image Processing (DIP). UTDC and high-speed camera were introduced for a more detailed measurement of the gas-liquid two-phase flow. As a result, the monitor of the gas-liquid two-phase flow became possible. The bubbly flow adapts the compound measurement system in this research. Furthermore, the each parameter effects for bubbly flow structures are clarified using the compound measurement system.
著者関連情報
© 2006 一般社団法人 日本機械学会