The Proceedings of the Fluids engineering conference
Online ISSN : 2424-2896
2010
Session ID : 1020
Conference information
1020 Noise Reduction Methods of Hole-tone Generating in Main Steam Stop Valve
Shiro TAKAHASHIAkinori TAMURANobuo SHIMONOShigekazu HORI
Author information
CONFERENCE PROCEEDINGS FREE ACCESS

Details
Abstract
There was a possibility that hole-tone was generated in a main steam stop valve (MSV) and caused the vibration and sound noise in the main steam line of the thermal power plant. To reduce the sound noise and vibration, scale air tests were conducted in the present study. Hole-tone broke out in Mach number more than 0.18. Low height slant tubs installed in the MSV seat completely suppressed the sound noise due to hole-tone.
Content from these authors
© 2010 The Japan Society of Mechanical Engineers