流体工学部門講演会講演論文集
Online ISSN : 2424-2896
会議情報
1003 正浸透モジュール内部の濃度分布と浸透性能(塩水流量と淡水流量の浸透性能に及ぼす影響)(OS10-1 再生可能流体エネルギーの利用技術,OS10 再生可能流体エネルギーの利用技術)
寺嶋 真伍林 秀千人奥村 哲也入江 守裕財津 慎一郎坂井 秀之
著者情報
会議録・要旨集 フリー

p. _1003-01_-_1003-03_

詳細
抄録
Forward osmosis(FO) is recently paied attention to preprocessing of the Reverse Osmosis(RO). It can reduce the input power of RO plant. It is required to do lower the salt concentration at outlet and higher the permeation flow rate for the supply flow rate. The characteristics of the flow and osmosis are studied for the hollow fiber membrane module that used in RO system. It is cleared in the membrane module with experiments that permeation flow rate is increased and the salt concentration at outlet is decreased with the lower salt water flow rate. The salt concentration distribution in the module becomes uniform with higher salt water flow rate. We proposed the parameter for evaluation of the FO performance. By this parameter, the FO performance is high at the low salt water flow rate.
著者関連情報
© 2013 一般社団法人 日本機械学会