流体工学部門講演会講演論文集
Online ISSN : 2424-2896
会議情報
1006 振動水柱型波力発電装置の空気室特性(OS10-2 再生可能流体エネルギーの利用技術,OS10 再生可能流体エネルギーの利用技術)
鈴木 正己永田 修一瀬戸口 俊明
著者情報
会議録・要旨集 フリー

p. _1006-01_-_1006-02_

詳細
抄録
The air chamber characteristics of oscillating water column (OWC) type wave power generator are shown. Since an orifice is used in many cases as load of OWC instead of the air turbine from the ease of an experiment when estimating the air chamber characteristics by experiment, there are many examples of study for the OWC characteristics using the orifice load. However, when treating as a linear problem, investigation about a dumping coefficient is based and this paper shows the air chamber characteristics about a dumping coefficient. Moreover, although research of OWC characteristics about the compressibility effect of air is carried out by the past, the more detailed investigation is performed here in.
著者関連情報
© 2013 一般社団法人 日本機械学会
前の記事 次の記事
feedback
Top