抄録
A local wall shear stress measurement method is proposed with a thin circular plate submerged in the wall layer. A calibration curve of pressure difference produced by the plate and near wall flow can be correlated with the local wall shear stress by a single analytical function for different plate thickness. For approaching angle of attack to the mean flow, the circular plate has well sensitive in comparison with the rectangular plate.