流体工学部門講演会講演論文集
Online ISSN : 2424-2896
セッションID: GS51
会議情報
GS51 テイラー・ディーン流れを利用したマイクロミキサの実験的研究 : 混合に及ぼす二次流れの影響
細田 駿介早水 庸隆柳瀬 眞一郎権田 岳森田 慎一大塚 茂山本 恭二
著者情報
会議録・要旨集 フリー

詳細
抄録
The micromixer, which has a rotor with a curved channel, is studied experimentally. The Taylor-Dean flow in a curved channel of rectangular cross-section is investigated using PIV (Particle Image Velocimetry) and LIF (Laser Induced Fluorescence) methods. Two walls of the channel (the inner and top walls) rotate around the center of curvature and a pressure gradient is imposed in the direction of the exit of the channel. The non-dimensional parameters concerned are the Dean number De and the Taylor number Tr. Photographs of the flow in a cross-section at 180° downstream from the curved channel entrance are taken by changing the flux (De) at a constant rotational speed (Tr) of the channel walls. It is found that good mixing performance is obtained in the case of De ≤ 0.1Tr. This tendency appears more strongly if aspect ratio is large. And we have confirmed the effect of secondary flow on the mixing.
著者関連情報
© 2015 一般社団法人 日本機械学会
前の記事 次の記事
feedback