709 体内完全埋め込み式電気機械駆動拍動流型左心補助人工心臓の開発現状
高橋 清文大内 克洋和栗 聡星 英男舟久保 昭夫中村 真人福井 康裕坂本 徹高谷 節雄
著者情報
会議録・要旨集 フリー

p. 187-188

詳細
抄録

Completely implantable electro-mechanical ventricular assist device (VAD) has been developed. This device is intended for the patients of 50-60kg weight. The blood pump housing is made of titanium alloy (Ti-6Al-7Nb) and flexing blood-contacting diaphragm is made of segmented polyurethane with MPC coating. In vitro and In vivo tests showed good performance as a left ventricular support device. For the further improvement of endurances, impact strength of the mechanical in the mock loop simulating the systemic circulatory condition resulted in possibilities of deterioration of endurance performance under the specific control condition. For the further improvements in higher endurance and higher efficiency, precise evaluation of optimal control patter of motor speed that will not prevent the pump for full fill condition is needed.