Abstract
In recent, numerous studies on BMI and BCI based on Berlin Brain Computer Interface, Rajesh P.N. Rao (University of Washington) and Kamitani (ATR) are reported. However, it is known that there have problems for the use of a direct input support device because the brain waves measurement requires considerable time and a device which large-scaled and large-amount such as the MRI. And, this analysis becomes difficult by irrationality brain waves coexisting to brain waves. In this research, we aim at developing real time and eye opened "Automatic Eye movement Discriminator" after preprocessing raw EEG with Emotiv Brain EEG pick up head-set. We observed the fundamental pattern for specified direction Eye-motion. This study reports "Automatic Eye movement Discriminator" using single signed channel sequences.