主催: The Japan Society of Mechanical Engineers
会議名: 第30回 原子力工学国際会議(ICONE30)
開催日: 2023/05/21 - 2023/05/26
This study aims to understand a time trend of the occurrence rate of steam generator (SG) tube leak in the existing sodium-cooled fast reactors (SFRs) based on the observed data. The target on SFRs in the present paper is Phenix in France and BN600 in Russia. From the open literature review, we investigated the number of tube-to-tubeplate weld, the number of tube-to-tube weld, heat transfer area of tube base metal, operating time of SGs, dates when SG tube leak occurred, leaked location, corrective action after tube leak such as replacement of leaked module. Based on these observed data, time to leak is estimated and then time trend of the occurrence rate of SG tube leak for each of the above-mentioned parts was quantitatively analyzed by the hazard plotting method. As a result, the rate of leak at tube-to-tube weld in Phenix shows increase with time due to probable cause of cyclic thermal stress in a short term. As for a long-term trend, the rate of tube leak in both Phenix and BN600 SGs indicated decrease with time probably thanks to improvement in welding and in SG operating condition and to removal of initial failure.