Proceedings of the International Conference on Power Engineering : ICOPE
Online ISSN : 2424-2942
2003.1
会議情報
D102 FEATURES AND OPERATIONAL RESULTS OF BIOMASS FIRED BUBBLING FLUIDIZED BED BOILER
Isao ToriiYoshihisa ArakawaHitoji YamadaTatsuo YokoshikiHiroshi Ohtani
著者情報
会議録・要旨集 フリー

p. _1-189_-_1-194_

詳細
抄録

Mitsubishi Heavy Industries. Ltd. has been developing the biomass fired bubbling fluidized bed boiler in recent years. The problem with regard to the gas emissions is that the simultaneous control of CO, NOx and dioxins is difficult, which is to say that on one hand CO and dioxins reduces in oxidized region with high temperature in freeboard, on the other hand NOx lowers in reducing region in bed. In order to reduce CO, NOx and dioxins simultaneously the air for the fuel combustion is separately fed into the furnace with four-staged air. The fluidized bed is maintained reducing zone in order to reduce NOx emission. The gas temperature rises with the secondary air injection for less CO and dioxins emissions. As a result of the boiler performance test, the emission levels of CO, NOx and dioxins are below the targeted values respectively in a satisfactory way.

著者関連情報
© 2003 The Japan Society of Mechanical Engineers
前の記事 次の記事
feedback
Top