Proceedings of the International Conference on Power Engineering : ICOPE
Online ISSN : 2424-2942
2003.2
会議情報
D202 The Influence on the Angular Momentum Flux by Changing the Sequence of the Whirl-depressing Air
Shifa DingPingyuan LiuChaosong ChenXingsheng HuLi ToaHanding CaoJinyuan Xu
著者情報
会議録・要旨集 フリー

p. _2-265_-_2-270_

詳細
抄録
There is often residual whirl at the furnace outlet of the tangentially-fired furnaces. It has serious influence on the safe operation of the boiler. It is well known that the large temperature imbalance of the flue gas and steam may be a serious threat to the safe operation of the superheater and the reheater. In the counter-tangential operation, some counter-tangential air-streams are used to depress the residual whirl intensity. However, there is some misunderstanding in counter-tangential operation, which does not take account of the particularities of the tangential firing. It only eliminates the whirl by itself. The controlled whirl method is put forward in this paper, which not only keep the advantage of the corner tangential firing, but also effectively controls the residual spin intensity at the furnace outlet. The numerical simulation was used in this paper to discuss some basic principles. It is shown how the angular momentum flux is influenced when various layer second air is used to depress whirl.
著者関連情報
© 2003 The Japan Society of Mechanical Engineers
前の記事 次の記事
feedback
Top