Proceedings of the International Conference on Power Engineering : ICOPE
Online ISSN : 2424-2942
セッションID: A211
会議情報
A211 Experimental and Numerical Investigations of the Double-Jet Film Cooling Technology(Gas Turbine-6)
Karsten KUSTERERAnas ELYASDieter BOHNTakao SUGIMOTORyozo TANAKAMasahide KAZARI
著者情報
会議録・要旨集 フリー

詳細
抄録
The Double-Jet Film-Cooling (DJFC) technology is invented by the authors and comprises a significant enhancement of the adiabatic film-cooling effectiveness due to the formation of anti-kidney vortices. The DJFC technology places a second ejection hole with compound angle in a double-hole arrangement downstream the first hole. The second hole creates a second jet with another dominating vortex rotating in opposite direction to the first one and then combines both jets to one jet (or double jet). The basic applicability and function of the DJFC technology has been proven by the numerical studies and testing in a test rig. The comparison of the experimental results of the adiabatic film cooling effectiveness to the numerical results for the same blowing ratio (e. g. M=0.5; M = (p * C)_c/(p * C)_h) shows qualitatively similar distributions. However, the experimental results show enhanced mixing-out of the cooling air and, thus, the experimental values of the adiabatic film cooling effectiveness are lower compared to the numerical values.
著者関連情報
© 2009 一般社団法人 日本機械学会
前の記事 次の記事
feedback
Top