Proceedings of the International Conference on Power Engineering : ICOPE
Online ISSN : 2424-2942
セッションID: ICOPE-15-C049
会議情報
ICOPE-15-C049 The engineering applications of ultra-super-critical double reheat steam turbine
Xiaodong ZhangYu FangMingjun HouQingzhou TangXin Wang
著者情報
会議録・要旨集 フリー

詳細
抄録
This paper introduces the 660MW ultra-supercritical double-reheat steam turbine developed independently by Dongfang Turbine CO.LTD (short for DTC). By improving the steam parameters, optimization of thermal system, using double reheat cycle, application of new high temperature materials, structure upgrading, such turbine parameters are successfully upgraded to 31MPa/600℃/620℃/620℃, power plant generation efficiency reached 46.6%. The unit with the world's highest parameters will be the first double reheat unit in China, provides a feasible path for the plan of energy saving and emission reduction, provides experience for the commercial operation of 700℃ level turbine in the future.
著者関連情報
© 2015 一般社団法人 日本機械学会