1205 ピン状フィン付き伝熱面をもつ二相自然循環ループによる冷却(GS-6 二相流・凝縮・凝固,研究発表講演)
今坂 三成忽那 泰章野口 佳樹塩見 洋一中西 重康
著者情報
会議録・要旨集 フリー

詳細
抄録
Heat generation from CPU of personal computer has increased, so more efficient cooling system is needed. This paper presents the result on performance of cooling system using two-phase natural circulation loop as a candidate for this purpose. Boiling on a finned surface that simulates CPU caused two-phase natural circulation. Results of boiling heat transfer showed higher value than Rohsenow-Clark correlation as the system pressure decreases. Also, this might be attributable to the effect of the finned surface. Possibility of cooling system by two-phase natural circulation loop was confirmed. By improving the condenser performances, the system can be applicable to the actual personal computer.
著者関連情報
© 2005 一般社団法人 日本機械学会