The Proceedings of Conference of Kanto Branch
Online ISSN : 2424-2691
ISSN-L : 2424-2691
2010.16
Session ID : 11820
Conference information
11820 Consideration on the Installation of Safety Plug Switch for Movable Guard
Makoto KimuraNoboru SUGIMOTO
Author information
CONFERENCE PROCEEDINGS FREE ACCESS

Details
Abstract
"Safety plug switch" is used for controlling hazardous energy in order to protect the machine maintenance personnel working at any place where they could be injured by the unexpected release of hazardous energy. In view of the above, this paper proposes that the relation of "withdrawing and possessing the safety plug for hostage control," "unlocking the movable guard for opening it" and "accessing to the working space" should be made unate in terms of system by applying the "principle of safety confirmation" to the safety plug switch installation. To realize such unite system, this paper formulates these interrelations, presents them in the form of interlock structure and shows an example of configuration that can meet the required functions.
Content from these authors
© 2010 The Japan Society of Mechanical Engineers
Previous article Next article
feedback