Quality Control of Tooth Contact of Gear using Infrared Ray Imagery
*Takahiro IIDAYasuhiro UENISHIToshiki HIROGAKIEiichi AOYAMA
Author information
CONFERENCE PROCEEDINGS FREE ACCESS

Details
Abstract
We propose a non-contact method using infrared ray thermography for measuring gear tooth contact to focus attention on the heat generated on the tooth surface at meshing. First, the radiation performance of the gear tooth surface and the effect of lubrication oil were investigated. Then, the reliability of this technique was evaluated by comparing with the observation result of tooth contact with komyotan which is traditional red paint for industrial use. Finally, the possibility of evaluating the meshing transmission error was shown. The results show this technique is effective for monitoring the contact pattern and confirming the tooth surface pressure.
Content from these authors
© 2007 The Japan Society of Mechanical Engineers