年次大会
Online ISSN : 2424-2667
ISSN-L : 2424-2667
セッションID: J022055
会議情報
J022055 MR based CFDによる脳動脈瘤WSS分布推定における血管形状抽出法および血液の非ニュートン性の影響
青木 康平大西 有希天谷 賢治清水 利恭礒田 治夫竹原 康雄小杉 隆司
著者情報
会議録・要旨集 フリー

詳細
抄録
Influence of vascular shape extraction method and Non-Newtonian hemodynamic behavior on WSS distribution estimation on cerebral aneurysm in MR based CFD is evaluated. Firstly, shapes of straight pipe are extracted from Contrast-Enhanced MRA (CE-MRA) image, Phase-Contrast MRA (PC-MRA) image and time avaraged PC-MRA image. With each extracted shape, WSS distribution is calculated using CFD. The WSS ditribution calculated with the shape extracted from CE-MRA image shows the good accuracy with the theoretical distribution, while the result with the shape extracted from PC-MRA images shows unsatisfactory accuracy. Secondly, the WSS distributions computed by CFD considering blood as between Newtonian fluid and Non-Newtonian fluid are compared. The Power Law model and Carreau model are employd as Non-Newtonian model. Because the results obtained with Newtonian model, Power Law model, and Carreau model were almost same, it is concluded that Newtonian model is valid enough to model the blood for evaluating WSS distribution.
著者関連情報
© 2012 一般社団法人 日本機械学会
前の記事 次の記事
feedback
Top