The Proceedings of Mechanical Engineering Congress, Japan
Online ISSN : 2424-2667
ISSN-L : 2424-2667
2012
Session ID : K05100
Conference information
K05100 Hydraulic Power Plant and Vacuum Cleaner
Yoshinobu TSUJIMOTOHiroshi TANAKA
Author information
CONFERENCE PROCEEDINGS FREE ACCESS

Details
Abstract
A high amplitude vibration of powerhouse occurred in a pumped storage power plant. Through detailed measurements of pressure fluctuation in the volute, it was found that the vibration was caused by a high amplitude pressure fluctuation in the volute and that the amplitude becomes the maximum at the runner speed where the rotational speed of the rotor-stator interaction mode agrees with the sound velocity in water. This phenomenon called phase resonance was simulated by air tests using a fan for vacuum cleaner and the fundamental characteristics were clarified by developing a one-dimensional theoretical model. This is a good example showing that we still have many interesting problems in turbomachinery although it is considered to be a mature field.
Content from these authors
© 2012 The Japan Society of Mechanical Engineers
Previous article Next article
feedback
Top