年次大会
Online ISSN : 2424-2667
ISSN-L : 2424-2667
セッションID: S022023
会議情報
S022023 プラスチック製人工椎体におけるFEM解析と力学試験の関連性
嶋津 賢了永村 和真瀬井 章砥上 若菜水田 博志日垣 秀彦中西 義孝
著者情報
会議録・要旨集 フリー

詳細
抄録
Biomechanical measurements are often performed by FEM analysis and Mechanical test but there are few reports which analyze the combination of FEM analysis and Mechanical test together to determine their relational accuracy. In the current study we use FEM and Mechanical tests to evaluate their relationship in a posterior lumber interbody fusion disorder in an effort to develop the Spinal interbody fusion implant. First, CAD data of the lumber spine (L4, L5) and lumber implant were created. FEM analysis and Compression test were performed with a load of 1000N and displacement was recorded. Only the anterior-superior aspect of the L4 lumber spine was displaced in the FEM analyses but the L4 was displaced downward overall in the Mechanical test. The boundary condition between the lumber spine and screw in the Mechanical test is fastened in a manner that allows transverse motion but is completely fixed in the FEM analysis. Improving the boundary conditions between the lumber spine and the screw in FEM analysis should help give close agreement with the results of the Mechanical test. Thereby improving the development of better Spinal interbody fusion spacer.
著者関連情報
© 2012 一般社団法人 日本機械学会