年次大会
Online ISSN : 2424-2667
ISSN-L : 2424-2667
セッションID: S083033
会議情報
S083033 キャニスタSCC防止に対する塩分流入低減装置
竹田 浩文三枝 利有
著者情報
会議録・要旨集 フリー

詳細
抄録
A natural ventilation system is generally adopted for storage facilities of spent nuclear fuel. At the storage facilities of concrete casks built near the seashore, the air including the sea salt particles comes into the concrete casks and could cause SCC of the canisters made of stainless steel. In this study, we proposed a salt particle collection device with low pressure loss which does not interfere with the air flow into the building or the concrete casks. Pressure loss tests in a laboratory and salt particles collection tests in the field were performed. Performance of the device adapted for the concrete cask was evaluated using obtained data.
著者関連情報
© 2012 一般社団法人 日本機械学会
前の記事 次の記事
feedback
Top