抄録
We developed a new diagnostic method by using laser beam. A tooth surface is irradiated by zonal laser beam from an oblique direction, and then the irradiated laser beam line is shifted along the height of the tooth according to gear rotation. The variation of the voltage proportional to laser reflection between initial and present conditions are compared, and it can be grasped condition on the tooth surface such as initial or abnormal abrasion, pitting, etc. We furthermore developed a method of automatic and remote damage diagnosis on a gear tooth surface according to various gear spec by using the angle-distance relation map which made from pre-measured data of a same material and heat-treating, and taking into account the influence of adjacent teeth. The measured data was agreed well with the predicted data made with this method, therefore we can diagnosis the condition of various products automatically.