F082003 各種蒸気流量計による湿り蒸気流量計測(【F08200】湿り蒸気流量計測,動力エネルギーシステム部門企画,先端技術フォーラム)
森田 良
著者情報
会議録・要旨集 フリー

詳細
抄録
It is well known that the wetness of steam flow sometimes causes measurement errors of the steam flow meter. However, it is difficult to clarify a particular error quantitatively in actual plants and factories, and thus far, there has been no established method for estimating the error caused by the wetness of steam flow. Therefore, wet steam flow rate measurement experiments were conducted to clarify the measurement error caused by the wetness of steam flow in a plant and a factory. We have conducted 3 types of the steam flow meter, orifice flow meter, vortex flow meter and ultrasonic flow meter. In this paper, we introduce the correlation between the measurement error and the flow condition and correction methods.