年次大会
Online ISSN : 2424-2667
ISSN-L : 2424-2667
セッションID: J052013
会議情報
J052013 クロスフローファンの干渉騒音の音源解析(〔J052-01〕流体関連の騒音と振動(1))
平田 陽平林 秀千人寺岡 弘宣
著者情報
会議録・要旨集 フリー

詳細
抄録
It is cleared in relating to interaction noise from cross flow fan with experiments and numerical simulation that the tongue shape affects the characteristic of sound source. Interaction noise becomes remarkable large at the operating point. There are three parts of sound sources on the tongue of the interaction noise. The first one is located at the end edge, the second one is located at the middle of the tongue and the third one in the round corner when the flow from impeller reaches to the tongue. The large interaction noise isn't generated at the round corner of the tongue where the very large pressure fluctuation is emerged. But the middle part of the tongue is the main source of interaction noise. It is proposed that the tongue shape is shortened at middle part of the tongue and the interaction noise is reduced with it.
著者関連情報
© 2013 一般社団法人 日本機械学会
前の記事 次の記事
feedback