The Proceedings of Mechanical Engineering Congress, Japan
Online ISSN : 2424-2667
ISSN-L : 2424-2667
2014
Session ID : F081001
Conference information
F081001 Influence of Wetness to Steam Flow Rate Measurement using a Vortex Flow Meter, and a Measurement Example using a Vortex Flow Meter at a Working Factory
Shuichi UMEZAWA
Author information
CONFERENCE PROCEEDINGS FREE ACCESS

Details
Abstract
Mainly steam is utilized as a means for thermal energy supply in industrial fields. It is important to be aware of the steam flow rate in the view point of energy management. However, steam becomes wet in many cases in the process to be sent through steam pipes to machinery using steam. It is well known that the wetness of steam sometimes causes measurement errors of the steam flow rate, and there has scarcely been the established method for estimating the influence caused by the wetness of steam flow. Accordingly, we conducted the experiments of wet steam flow rate measurement to clarify the measurement error caused by the wetness of steam. This paper reports the measurement using a vortex flow meter, following our previous paper using an orifice flow meter. As a result, the correlation between the measurement error and the flow condition was clarified. And a measurement example using vortex flow meters to heat consumption of drying process at a working factory is introduced
Content from these authors
© 2014 The Japan Society of Mechanical Engineers
Previous article Next article
feedback
Top