年次大会
Online ISSN : 2424-2667
ISSN-L : 2424-2667
セッションID: W051001
会議情報
W051001 荷電ナノ粒子流の計測 : イオン電流とトンネル電流([W05100]流体工学部門企画,先端熱流体計測の計算との連携を含む新展開)
川野 聡恭
著者情報
会議録・要旨集 フリー

詳細
抄録
To electrically detect the nanoparticles such as pollen allergens or biomolecules by the use of gating nanopore technologies, the rapid change of ion current induced by the ion flow with the translocation of the charged particle should be precisely measured. From the direct or statistical evaluations of the current change, the identification of molecules, e.g., DNA bases, becomes to be practical. When the nanoparticles translocate through the nanopore, the ion current decreases because the particle prevents the path of ion flow between the electrodes, and it is well known as the principle of the Coulter counter. On the other hand, in some special cases of nanopore size and the molecular structures, it can be observed that the detected current increases during the translocation. It must be so-called the tunnel current which is from quantum mechanical effects. In this paper, the theoretical backgrounds of ion and tunnel currents detections, and the comparison with experimental results are introduced.
著者関連情報
© 2014 一般社団法人 日本機械学会