年次大会
Online ISSN : 2424-2667
ISSN-L : 2424-2667
セッションID: J2220305
会議情報
J2220305 バイオレジストを用いたマイクロバブルの流量特性
高桑 暁伊藤 啓太郎溝尻 瑞枝櫻井 淳平新井 史人秦 誠一
著者情報
会議録・要旨集 フリー

詳細
抄録
We proposed a microvalve using photoprocessible thremoresponsible gel, which is called "Bioresist". Bioresist has characteristic of shrinking higher than 32 degree Celsius and swelling lower than 32 degrees. The volum change is utilized for opening and closing the microvalve. Since Bioresist is patterned, we can fabricate any arbitrary 2D shape of Bioresist using photolithography. We developed a microvalve which can control opening and closing by integrating the patterned Bioresist with a microheater using MEMS technology. The microvalve using Bioresist hasthe advantage of high speed response and low power consumption. We evaluated the relationship between applied current required for opening the microvalve and flow rate when microvalve were tested under regular pressurized flow with de-ionized (DI) water. As a result, flow rate is proportional relationship with applied current. It was shown controllability of flow rate by applied current.
著者関連情報
© 2015 一般社団法人 日本機械学会
前の記事 次の記事
feedback
Top