主催: 一般社団法人 日本機械学会
会議名: 2016年度 年次大会
開催日: 2016/09/11 - 2016/09/14
Experimental observations on the trigger mechanisms for the departure from nucleate boiling in subcooled flow boiling in a vertical, single-tube with an inner diameter of 4 mm and heated length of 5 mm are presented. In this study, a transparent heated tube is used. The tube is made of Pylex glass which inner wall is covered with extremely thin gold film, and it can be measured the inner wall temperature and observated flow behaviour simulataniously. Experiments used FC-72 as a test fluid are counducted under the conditions of G=400-1000 kg/m2s, ΔTsub=30 K, qin=464-673 kW/m2. Three indicators, dry patch area, three-phase interfacial length and two-dimensional projected gas-liquid interfacial area (2D-PGIA) are drived from high-speed images. 2D-PGIA that is proposed in this study is a new indicatior, it can be considerd as a simple expression of interfacial area concentarion. The results indicate the possibility that the reduction of 2D-PGIA at constant heat flux condition is the trigger of DNB.