The Proceedings of Mechanical Engineering Congress, Japan
Online ISSN : 2424-2667
ISSN-L : 2424-2667
[volume title in Japanese]
Session ID : S0540204
Conference information

Temperature rise factors and measures in Yamate tunnel
Motomasa MATSUZUKIAkisato MIZUNOHirotaka YANAGI
Author information
CONFERENCE PROCEEDINGS FREE ACCESS

Details
Abstract

This paper describes measures to suppress the temperature increase inside tunnels on urban roads. The Yamate Tunnel is a long tunnel extending a total of 18km in the center of Tokyo. The tunnel interior temperature has increased during the summer. Motorcycle riders have complained about the heat inside the tunnel. So we investigated and analyzed the causes of the temperature increase. To suppress the increase of the temperature, we installed mist spraying equipment inside the tunnel. This system successfully cooled the inside of the tunnel. Furthermore, we compared the calculated value to the measured value of the temperature in the tunnel.

Content from these authors
© 2016 The Japan Society of Mechanical Engineers
Previous article Next article