年次大会
Online ISSN : 2424-2667
ISSN-L : 2424-2667
2016
セッションID: S0540401
会議情報

道路トンネル火災時の低風速化煙制御と縦断勾配による影響
江本 信司清家 美帆川端 信義長谷川 雅人
著者情報
会議録・要旨集 フリー

詳細
抄録

Since tunnel spaces are long and enclosed, there are threats that a large number of casualties are caused by thermal fume and smoke propagation in fires. Therefore, the low-speed ventilation control system has been adopted in Japan to control the longitudinal velocity in event of tunnel fire. In recent year, the number of tunnels with steep longitudinal inclination is increasing. The effects of the low-speed ventilation control system in tunnels with inclinations of -3%, 0%, and 3% have been investigated in the present paper. It was clarified that thermal fume in the cases with longitudinal inclinations made the evacuation environment worse. However, the number of sufferers surrounded by dense smoke can be reduced with appropriate ventilation velocity.

著者関連情報
© 2016 一般社団法人 日本機械学会
前の記事 次の記事
feedback
Top