年次大会
Online ISSN : 2424-2667
ISSN-L : 2424-2667
2018
セッションID: S0810002
会議情報

大崎クールジェン酸素吹IGCC実証プロジェクトの進捗状況
*竹村 亮介
著者情報
キーワード: Coal gasification, IGCC, IGFC, CO2 capture, CCT
会議録・要旨集 フリー

詳細
抄録

Coal-fired power plants, which provide stable power at low cost, will continue to serve as base load supporting the world's increasing power demands. However, the amount of CO2 emitted by coal utilization is larger than that of other fossil fuels. Therefore the Osaki CoolGen Project has been launched to realize innovative HELE (High Efficiency, Low Emissions) coal-fired power generation which combines an Integrated coal Gasification Combined Cycle (IGCC) / Integrated coal Gasification Fuel Cell combined cycle (IGFC) with CO2 capture. This project is subsidized by the Ministry of Economy, Trade and Industry (until 2015 FY) and New Energy and Industrial Technology Development Organization (from 2016 FY). The oxygen-blown IGCC demonstration test, which is the base technology for IGFC, commenced in March 2017. We've achieved world-class net efficiency, environmental performance, plant reliability and flexibility. Construction of CO2 capture unit started in April 2018 and is underway to start demonstration test.

著者関連情報
© 2018 一般社団法人 日本機械学会
前の記事 次の記事
feedback
Top