加熱円板周りの噴流の可視化および伝熱係数分布の評価
*王 天舒田之上 健一郎
著者情報
会議録・要旨集 認証あり

詳細
抄録

In this study, the effect of the vertical direction and nozzle diameter dN on heat transfer on the heated disc in cylindrical flow channel was investigated. When the heated disc was installed vertically downward (+g), for dN = 10mm the Nusselt number Nu had a maximum value at the center of the disc due to impinging jet flow while for dN = 180 mm the Nu had a maximum value at the edge of the disc due to natural convection. The average Nusselt number Nuav along the radial direction on the disc decreased drastically with Richardson number Ri. The validation of the Nusselt number ζ had a minimum value of about 0.5 at 100 < Ri < 10000. On the other hand, when the heated disc was installed vertically upward (-g), the Nu became almost uniform along the radial direction on the heated disc for dN > 50 mm. The Nuav was two times higher than that for +g condition while the ζ had about 0.2 at (-Ri) > 100000.