抄録
An axial flow cyclone dust collector with fixed guide vanes (called simply as a cyclone) is applied in many industrial fields. Therefore, it is used widely in all over the world. However, the report of collection performance depended shape of outlet pipe is very few. Then, this paper describes about the collection efficiency and pressure drop by the difference between cylindrical exit pipe and funnel shape, when main size of the test cyclone is fixed as Separatin chamber diameter : D_1=99 (mm), Boss diameter : D_B=47 (mm), Imaginaly cylindrical length : Hi=134 (mm) and the angle of fixed guide vanes : θ_B=45°